Test ID:1.3.6.1.4.1.25623.1.0.103907
Category:Web application abuses
Title:Siemens Scalance X-200 Series Switches Insufficient Entropy Vulnerability
Summary:Siemens Scalance X-200 Series switches are prone to a; vulnerability in the entropy of random number generator.
Description:Summary:
Siemens Scalance X-200 Series switches are prone to a
vulnerability in the entropy of random number generator.

Vulnerability Insight:
By requesting /fs/cfgFile.cfg it is possible to read the config
of the remote device.

Vulnerability Impact:
Remote attackers can exploit this issue to hijack web sessions
over the network without authentication. Other attacks are also possible.

Affected Software/OS:
Siemens Scalance X-200 Series switches running firmware
versions prior to 5.0.0 are vulnerable.

Solution:
Updates are available.

CVSS Score:
8.3

CVSS Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:C

Cross-Ref: Common Vulnerability Exposure (CVE) ID: CVE-2013-5709
http://ics-cert.us-cert.gov/advisories/ICSA-13-254-01