Test ID:1.3.6.1.4.1.25623.1.0.143936
Category:Huawei
Title:Huawei Data Communication: Integer Overflow Vulnerability in Some Huawei Devices (huawei-sa-20161123-01-vrp)
Summary:Some Huawei devices have an integer overflow vulnerability.
Description:Summary:
Some Huawei devices have an integer overflow vulnerability.

Vulnerability Insight:
Some Huawei devices have an integer overflow vulnerability. Due to the lack of validation in some field of the packet, a remote, unauthenticated attacker may craft specific IPFPM packets, probably causing the device to reset. (Vulnerability ID: HWPSIRT-2016-04030)This vulnerability has been assigned a Common Vulnerabilities and Exposures (CVE) ID: CVE-2016-8795.Huawei has released software updates to fix this vulnerability. This advisory is available in the linked references.

Vulnerability Impact:
Successful exploit may cause the device to reset.

Affected Software/OS:
Secospace USG6600 versions V500R001C00

Solution:
See the referenced vendor advisory for a solution.

CVSS Score:
7.1

CVSS Vector:
AV:N/AC:M/Au:N/C:N/I:N/A:C

Cross-Ref: Common Vulnerability Exposure (CVE) ID: CVE-2016-8795
BugTraq ID: 94504
http://www.securityfocus.com/bid/94504